Temperature Controls & Sensors
Digital Temperature Controllers unit with D1/16 Din Digital Thermostats Single Setpoint sensor
Digital Temperature Controllers unit with D1/16 Din Digital Thermostats Single Setpoint sensor
Digital Temperature Controllers unit with D1/16 Din Digital Thermostats Single Setpoint sensorSimple to Set and Operate 1/16 DIN Size ControllersThis multi-range 1/16 DIN controller with alarm function offers field-selectable PID control or ON/OFF control. The large, single display shows process value, direction of deviation from set point, output and alarm status.Easy setting using internal DIP and rotary switchesON/OFF or PID control (with on-demand auto-tuning) selectableClearly visible digital display with character height of 13.5 mmDeviation indicator makes monitoring more effectiveMultiple temperature sensor input (thermocouple/platinum resistance thermometer) models stocked; thermocouple input only and platinum RTD input only models availableModels with two alarms are ideal for temperature alarm applicationsSetting change protection prohibits tamperingSampling rate (500 ms) and selectable control period (2 and 20 s) improves response8-mode alarm output and sensor error detection“Input shift” function adjusts display to reflect known sensor offsets      • ° C or ° F field selectable      • Black or white cases available to match panel aesthetics • RoHS compliant      • Water-resistant front panel rated NEMA 4X/IP66      • Compact: measures 48 H x 48 W x 78 D mm      • Accuracy ±0.5% of valueAll setting field configurable with switchesMulti-input (Thermocouple/Pt100)Clearly visible 3.5-digit display with character height of 13.5mmControl output: relay, voltage (for driving SSR)ON/OFF or 2-PID control with auto-tuning and self-tuningAlarms2 RelayControl functionHeat or coolControl methodON/OFF-control, PID controlDisplaySingle line, deviation indicatorIP ratingIP66Size1/16 DIN (48x48 mm)Intuitive operator guidanceClear indication that the correct temperature has been reached thanks to the deviation indicator.Speed-up your lineExcellent control, especially in this disturbance-sensitive application.Usage in harsh environmentThe flat front makes the use of the E5CSV hygienic and it's easy and safe to clean thanks to its IP66 rating.
CE Conductive Liquid Level Control
CE Conductive Liquid Level Control
CE Conductive Liquid Level ControlLevel probes & Float Switches(PP/PVDF)Provides automated control and consistent liquid levels in most conductive aqueous processes, waste treatment tanks and when leak detection is required.Adds protection against damage and tank fires associated with low-level conditions.Probe enclosure: vapor tight, flame retardant, polyproylene head with 10-foot (3m) flexible cord and quick connect plug for easy connection to remote circuitry.Two probe units (LP-2): for single point control. Multi probe units (LP-3): for two-point control and refill/pump down applications. 4,5 or 6-probe devices for multiple level control applications, LCBA5 - Level switch electronics (only) mounted in plastic enclosure. 2-probe unitsElectronic Assembly field selectable voltage 120/240V.LCBE5 - Level switch electronics (only) mounted in plastic enclosure. 3-probe unitsElectronic Assembly field selectable voltage 120/240V.Control enclosure: gasketed NEMA 1, IP21 flame retardant, polypropylene box with stainless steel hardware.*Specify probe material: (S) = STAINLESS STEEL, (T) = TITANIUM, (H) = HASTELLOY C, (G) = GRAPHITE (not field trimmable). (FLUOROPOLYMER (PTFE) COVERED STANDARD)Features and Benefits:IMPROVES PROCESS CONTROL:Provides automated control and consistent liquid levels in most conductive aqueous processes, waste treatment tanks and when leak detection is required.Adds protection against damage and tank fires associated with low-level conditions.Two probe units: for single point control.Multi probe units: for two-point control and refill/pump down applications.CORROSION RESISTANT PROBES:Fluoropolymer (PTFE) covered: 316 stainless steel, titanium, Hastelloy C and graphite tipped Hastelloy probe materials.Lengths: up to 48 inches (1220mm) standard.Field trimmable (except graphite probes).CORROSION RESISTANT ENCLOSURES:Control enclosure: gasketed NEMA 1, IP21 flame retardant, polypropylene box with stainless steel hardware.Probe enclosure: vapor tight, flame retardant, polypropylene head with 10-foot (3m) flexible cord and quick connect plug for easy connection to remote circuitry.CERTIFICATIONS:cULus and CE.CAPACITIES:Relay rating: 10-amps at 120 to 240 volts, 50/60Hz, single pole, double throw.Sensing output: 14.5 VAC.Ambient temperature range: 0°F (-18°C) to 104°F (40°C).Maximum solution resistance: 70,000 ohm-CM.Single phase only.SAFETY FEATURES:Ground connection on circuit board.Minimal AC sensing current has no affect on plating processes.OPTIONS AVAILABLE (consult factory):Probe lengths up to 20-foot (6m).LC circuit board can be pre-wired into combination controls.Fluid stilling chambers.Longer probe cords.Probe cord extensions for existing units.4, 5 or 6-probe devices for multiple level control applications.
Temperature Probes with PT100 sensor
Temperature Probes with PT100 sensor
Temperature Probes with PT100 sensorPT100 RTD Sensor - Pt100 temperature sensor - RTD - PT100 - Sensor MeasurementElectrode Level SensorAccurate monitoring of liquid levels in tanks and containers is essential to ensure a smooth process and prevent unwanted variations such as evaporation or leaks. Electrode level sensors are designed to effectively regulate and monitor liquid levels in various industrial applications, thus ensuring a secure and reliable operation of processes.Level Detector: Precise Control Level detectors provide precise monitoring of maximum and minimum levels in industrial applications. With the option to use 2 to 5 electrodes to detect up to 4 different levels, these devices offer a versatile and efficient solution. Additionally, they can be equipped with an integrated temperature probe for additional functionality. NS/NT Level Measurement The operation of electrode level detectors is based on the principle of conductivity and is only guaranteed in liquids conducting electricity (conductivity 10µS). As electrode level detectors are purely passive sensors, they need to be connected to processing electronics (ETS100, ENR200/300) for operation.PRODUCT DESCRIPTIONProvides automated control and consistent liquid levels for most aqueous processes and waste treatment tanks, or when leak detection is required.FEATURESHelps protect against fires and tank damage associated with low-level conditions.Dual probe units: for single point control. Multi probe units: for two-point control and refill/pump down applications.Fluoropolymer (PTFE) covered: 316 stainless steel, titanium, Hastelloy C® and graphite tipped Hastelloy probe materials.Control enclosure: gasketed UL Type 1, IP21 (indoor) polypropylene box with stainless steel hardware.Probe enclosure: vapor resistant polypropylene head with 10-foot (3m) flexible lead and quick connect plug for easy connection to remote circuitry.Certifications:CE compliant.SPECIFICATIONSRelay rating: 10-amps at 120/208 to 240 volts, 50/60 Hz, single pole, double throw.Sensing output: 14.5 VAC.Ambient temperature range: 0°F (-18°C) to 104°F (40°C).Maximum solution resistance: 70,000 ohm-CM.Ground connection on circuit board.OPTIONS AVAILABLE (CONSULT FACTORY)Probe lengths up to 20-foot (6m).Can be pre-wired into combination controls.4, 5 or 6-probe devices for multiple level control applications.
Copyright © 2013 Guangzhou Precise Heater Co.,LTD.All Rights Reserved 犀牛云提供企业云服务